Trane Furnace: Downflow furnace on combustible floor (subbase)
Downflow furnace on combustible floor (subbase) on a Trane furnace: DH1 downflow on a combustible floor. Can't sit it right on carpet, tile or any combustible flooring. Wood flooring is the exception. Use the subbase.
Applies to: DH1 downflow furnaces
Common causes of downflow furnace on combustible floor (subbase)
- Not a fault. Floor protection requirement for a downflow install.
How to fix downflow furnace on combustible floor (subbase): step by step
- Put subbase BAYBASE-205 between the furnace and combustible flooring on vertical downflow installs.
- Downflow vertical with a cased coil? No subbase needed.
- Cut the floor opening to the dimensions in Table 1.
- Check the opening is square and clear of joists or wiring.
- Seat the furnace on the subbase and confirm no gaps around it.
- Check clearances to combustibles on the rating plate before leaving.
If the unit shows an error code, look it up: Trane Furnace codes
Models
DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601
Source: Trane installer's guide 18-CD29D1-11, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.