Trane Furnace: Vent and inlet air connection and pipe support

Updated · by Aurora Star Tech Inc.

Vent and inlet air connection and pipe support on a Trane furnace: Pipe joints have to be fastened and sealed so combustion products stay out of the building. Think of it as two jobs. The inlet is a friction fit sealed so it can come apart for service. The vent pipe is connected to the vent collar the same way, with RTV, so you can separate it later. Keep both pipes supported along their whole length, and terminate them in the same pressure zone, otherwise the pressure switch will nuisance trip.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vent and inlet air connections

Common causes of vent and inlet air connection and pipe support

  • Flue gas leaking at an unsealed or loose joint
  • Pipes unsupported and sagging, stressing the joints
  • Vent and inlet ending in different pressure zones
  • Joints glued solid so the furnace cannot be serviced or moved

How to fix vent and inlet air connection and pipe support: step by step

  1. Make the combustion air inlet connection a friction fit. Seal the inlet joint with RTV so it can be separated for service.
  2. Connect the vent pipe to the vent collar with RTV sealant so it can be separated later for service or clearance.
  3. Support the inlet and vent pipes along their entire length.
  4. Keep the vent and inlet in the same pressure zone so the vent lengths stay valid.
  5. Terminating in different pressure zones can cause nuisance pressure switch trips. If zones differ, the inlet must be in the higher (more positive) zone.
  6. Check for flue gas leaks after the first run.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Source: Trane AUH1B080A9421B installer's manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977