Trane Furnace: Abnormal conditions and protection
Abnormal conditions and protection on a Trane furnace: Summary of how the furnace responds to abnormal conditions.
Applies to: AUH1B furnaces
Common causes of abnormal conditions and protection
- Excessive combustion pressure from wind over 40 mph or vent/flue blockage
- Loss of flame during heating
- Power failure during heating
- Gas supply failure
- Induced draft blower failure
- Condensate drain blockage
How to fix abnormal conditions and protection: step by step
- Excessive pressure: pressure switch opens and shuts off gas until pressure is acceptable.
- Loss of flame: control closes gas valve, retries ignition, then locks out if ignition fails.
- Power failure: ignition restarts automatically when power returns if thermostat still calls for heat.
- Draft blower failure: unit will not start if pressure is not sensed.
- Condensate blockage: pressure switch stays open until the drain is cleared and condensate flows freely.
- Lockout: reset manually as described in the reset tip.
If the unit shows an error code, look it up: Trane Furnace codes
Source: Trane installer's manual (AUH1B040A9241A), p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.