Trane Error Code Ht: Gas heating (single-stage models) (Furnace)
Trane error code Ht on a furnace means: Gas heating (single-stage models). It is also called Trane diagnostic code Ht.
Homeowner? What Trane code Ht means for you
Usually minor Your furnace is reporting: Gas heating (single-stage models). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Trane error code Ht mean?
S8B1 and S8X1 show Ht during a gas heat call, alternating with the airflow tap readout. The legend lists Ht as the single-stage label for Ht1.
Applies to: S8B1 and S8X1
Trane models that use code Ht
S8B1A026M2PSABS8B1A040M3PSABS8B1B040M2PSABS8B1B060M3PSABS8B1B060M4PSABS8B1B080M4PSABS8B1C080M5PSABS8B1C100M5PSABS8B1D120M5PSABS8X1A026M2PSABS8X1A040M3PSABS8X1B040M2PSABS8X1B060M3PSABS8X1B060M4PSABS8X1B080M4PSABS8X1C080M5PSABS8X1C100M5PSABS8X1D120M5PSAB
Other Trane Furnace codes
All Trane Furnace error codes →
Trane code Ht: homeowner questions
What does Trane code Ht mean?
Gas heating (single-stage models). S8B1 and S8X1 show Ht during a gas heat call, alternating with the airflow tap readout. The legend lists Ht as the single-stage label for Ht1.
Is it safe to keep using my furnace with code Ht?
Usually yes. Code Ht is normally minor, but if it keeps coming back have it checked.
Can I reset Trane code Ht myself?
You can try one reset (power off for 30 seconds, then on). If Trane code Ht comes back, the cause is still there and a licensed technician should check it.
Who can fix Trane code Ht near me?
Aurora Star Tech Inc. repairs Trane furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
- Cycles on limit (not lockout) All brands · Furnace
- Does not start All brands · Furnace
- Flame burns a few seconds then out All brands · Furnace
- Flame conditions table All brands · Furnace
- Heat exchanger leak All brands · Furnace
- High blower-door ACH50 (>3) All brands · Furnace
- High fuel consumption All brands · Furnace
- High stack temperature All brands · Furnace
- High stack temperature / low efficiency All brands · Furnace
- Indoor blower runs, outdoor unit dead All brands · Furnace
- Limit opens All brands · Furnace
- Locks out — oil but no ignition All brands · Furnace
- Low CO2 (<8 %) All brands · Furnace
- Low draft / blowback All brands · Furnace
- Modulating furnace won't modulate All brands · Furnace
- Negative house pressure, backdrafting, infiltration All brands · Furnace
- No heat All brands · Furnace
- No heat All brands · Furnace
- No heat (ignition stage) All brands · Furnace
- Noisy All brands · Furnace
- Noisy registers, drafts, blower overamps/ECM noise, coil freezing All brands · Furnace
- Not running / fault code All brands · Furnace
- Oil + ignition OK but no flame All brands · Furnace
- Oil on floor All brands · Furnace
- Pressure switch open / stuck All brands · Furnace
- Puff-back / delayed ignition All brands · Furnace
- Reduced airflow, hot motor All brands · Furnace
- Reduced pressure, smoky shutdowns, lockouts All brands · Furnace
- Rollout switch tripped All brands · Furnace
- Short cycling All brands · Furnace
- Smoke, soot, odour, pulsation All brands · Furnace
- Starts but locks out — no oil at nozzle All brands · Furnace
- Too little / too much air All brands · Furnace
- Unsatisfactory heat (short cycles / uneven / not enough) All brands · Furnace
- Water flows with furnace off All brands · Furnace
- Read or clear the last 6 faults (L6F menu) Trane · Furnace
- Reading and clearing fault history - Trane S-Series IFC Trane · Furnace
- Reset the control to factory defaults Trane · Furnace
- Run test mode (furnace) Trane · Furnace
Source: Trane S8B1/S8X1/S8X2 installation 18-CE14D1-1A-EN, System Status Menu, p.57; Sequence of Operation, p.60. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.