Trane Furnace: Choose combustion air method: confined or unconfined space
Choose combustion air method: confined or unconfined space on a Trane furnace: Before anyone sizes combustion air openings, you have to decide whether the furnace sits in a confined or unconfined space. I see this missed on basement and closet installs more than almost anything else, and it is how you end up with spillage, sooting and CO problems. The test is volume against total input of everything burning fuel in that space, not just this furnace. Tight modern houses can behave as confined even when the volume looks big enough.
Applies to: All UH1/DH1 gas furnaces
Common causes of choose combustion air method: confined or unconfined space
- Furnace in a closet or small utility room with a water heater or other appliance
- Tightly built house where infiltration will not supply enough air
- Spaces exposed to chemicals, such as pools, laundry or craft rooms, or near chemical storage
- Replacement of an old furnace where the room has since been sealed up
How to fix choose combustion air method: confined or unconfined space: step by step
- Treat the space as confined if it has less than 50 cu ft per 1000 BTU/hr input from all installed equipment
- For an unconfined space, check whether infiltration is enough. Tight construction may need added air as for a confined space
- Use outdoor air where chemical exposure is likely, such as commercial buildings, indoor pools, confined laundry or craft rooms, or near chemical storage
- For a confined space, supply air from inside (two openings to an adjoining room of enough volume)
- Or supply air from outdoors (two openings, one within 12 in of the top and one within 12 in of the bottom)
- Check local code for opening sizes, and have a licensed gas fitter confirm the final setup
If the unit shows an error code, look it up: Trane Furnace codes
Models
DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601
Source: Trane installer's guide 18-CD29D1-11, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.