Trane Furnace: Upflow furnace with cased coil attachment
Upflow furnace with cased coil attachment on a Trane furnace: Before you set a factory cased coil on a Trane UH1 upflow furnace, read the installer's guide and gather the standoffs and screws that came with the coil. The coil mounts to the top flanges of the furnace and always sits downstream of the furnace airflow. Shut off power and gas to the furnace while you work.
Applies to: Upflow UH1 furnaces with cased coil
Common causes of upflow furnace with cased coil attachment
- Not a fault call. This is a mounting procedure for an upflow furnace with a cased coil.
How to fix upflow furnace with cased coil attachment: step by step
- Use the standoffs and screws included with the cased coil, and do not substitute hardware.
- Locate the clearance alignment holes near the bottom of the coil wrapper.
- Insert each standoff into the cabinet alignment hole.
- Drive the drill screws through the standoffs and into the furnace top flange.
- Confirm the coil sits square and the joint between coil and furnace is tight.
- Seal any gaps per the installer's guide so conditioned air does not leak.
If the unit shows an error code, look it up: Trane Furnace codes
Models
DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601
Source: Trane installer's guide 18-CD29D1-11, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.