Trane Error Code E05: Flame sensed when no flame should be present (Furnace)
Trane error code E05 on a furnace means: Flame sensed when no flame should be present. It is also called Trane diagnostic code E05.
Homeowner? What Trane code E05 means for you
Stop and call Your furnace is reporting: Flame sensed when no flame should be present. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Trane error code E05 mean?
The control detects flame with the gas valve supposed to be closed, typically a leaking valve. On the S8X manual this code is printed as e0s.
Applies to: Trane S8V2 (80%, 2-stage, variable speed, Link) and S8B1 / S8X1 / S8X2 (80%, 1- and 2-stage)
Common causes of Trane code E05
- Gas valve leaking through
- Water or dirt in the valve inlet screen
- Missing drip leg
Trane models that use code E05
Show all 37 models
S8B1A026M2PSABS8B1A040M3PSABS8B1B040M2PSABS8B1B060M3PSABS8B1B060M4PSABS8B1B080M4PSABS8B1C080M5PSABS8B1C100M5PSABS8B1D120M5PSABS8V2A040M3PCBS8V2A040M3PDS8V2B060M4PCBS8V2B060M4PDS8V2B080M4PCBS8V2B080M4PDS8V2C080M5PCBS8V2C080M5PDS8V2C100M5PCBS8V2C100M5PDS8V2D120M5PCBS8V2D120M5PDS8X1A026M2PSABS8X1A040M3PSABS8X1B040M2PSABS8X1B060M3PSABS8X1B060M4PSABS8X1B080M4PSABS8X1C080M5PSABS8X1C100M5PSABS8X1D120M5PSABS8X2A040M3PSABS8X2B060M3PSABS8X2B060M4PSABS8X2B080M4PSABS8X2C080M5PSABS8X2C100M5PSABS8X2D120M5PSAB
Other Trane Furnace codes
All Trane Furnace error codes →
Trane code E05: homeowner questions
What does Trane code E05 mean?
Flame sensed when no flame should be present. The control detects flame with the gas valve supposed to be closed, typically a leaking valve. On the S8X manual this code is printed as e0s.
Is it safe to keep using my furnace with code E05?
No. Code E05 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.
Can I reset Trane code E05 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Trane code E05 near me?
Aurora Star Tech Inc. repairs Trane furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blowing cold air All brands · Furnace
- No heat All brands · Furnace
- Short cycling All brands · Furnace
- Reading and clearing fault history - Trane S-Series IFC Trane · Furnace
Source: Trane FNR-SVX003A-EN (S8V2 installer's guide) - section Integrated Furnace Control Display Codes, Table 37 Error codes; Trane FNR-SVX003A-EN (S8V2 installer's guide) - section Troubleshooting (flowcharts); Trane 18-CE14D1-1A-EN (S8B1/S8X1/S8X2 installer's guide) - section Integrated Furnace Control Display Codes, Error Codes. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.