Trane Furnace: Stainless steel vent fitting installation
Stainless steel vent fitting installation on a Trane furnace: Type 29-4C stainless fittings are required for masonry chimney and some roof venting. Orientation and sealing matter, because leaks put flue gas into the building.
Applies to: Stainless steel venting
Common causes of stainless steel vent fitting installation
- Male end of a fitting facing away from the furnace, so condensate leaks out
- Seam not on top of horizontal sections
- Unsupported long horizontal sections that sag, and unsealed joints
How to fix stainless steel vent fitting installation: step by step
- Use Type 29-4C single wall stainless fittings throughout where stainless venting is called for.
- Install all stainless fittings with the male end toward the furnace.
- Put the seam on top for all horizontal stainless sections.
- Support long horizontal sections to prevent sagging.
- Fasten and seal all pipe joints to prevent flue gas escaping into the building.
- Check for leaks with the furnace running.
If the unit shows an error code, look it up: Trane Furnace codes
Models
UH1B040A9241AUH1B060A9361AUH1B080A9421BUH1C080A9601AUH1C100A9481AUH1D100A9601AUH1D120A9601A
Source: Trane installer's guide, p. 23. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.