Trane Furnace: Gas piping installation

Updated · by Aurora Star Tech Inc.

Gas piping installation on a Trane furnace: Gas piping to the furnace is simple once you know the rules. Upflow units ship set up for left-side gas piping, and there is a right-side knockout if the gas comes in from the other side. What matters is sizing the pipe for the load, putting in a shutoff and union so the furnace can be serviced, and a drip leg to catch dirt and moisture before it reaches the gas valve. Always leak-test with soap solution, never a flame.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Gas supply connection

Common causes of gas piping installation

  • Undersized pipe starving the furnace at full fire
  • No drip leg letting debris reach the gas valve
  • Gas valve damaged by wrenching without a backup
  • Wrong pipe compound on propane
  • Leaking joints from poor assembly

How to fix gas piping installation: step by step

  1. Size piping using the pipe capacity table for the required cfh and run length.
  2. Install a ground joint union and a manual shut-off valve ahead of the furnace.
  3. Install a condensation drip leg ahead of the controls as required by national codes.
  4. Use a backup wrench on the gas valve when connecting piping to prevent damage.
  5. Use pipe joint compound that resists liquefied petroleum gases.
  6. Check all gas joints for leaks with soap solution. Never use an open flame.
  7. Have a licensed gas fitter do the work and do a final leak check with the furnace firing.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Source: Trane 18-CD29D1-11 installer's guide, p. 35. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977