Trane Furnace: Preliminary inspections before lighting
Preliminary inspections before lighting on a Trane furnace: Check these items with gas and electrical power off.
Applies to: Furnace startup
How to fix preliminary inspections before lighting: step by step
- Confirm duct connections are sealed.
- Confirm filters are in place.
- Confirm venting is properly assembled.
- Confirm the blower door is in place.
- Set the gas valve switch to OFF, open the external gas valve, and purge air from the lines.
- Leak check all gas connections with soapy solution, then wait 5 minutes for any gas to clear. LP gas is heavier than air and may need forced ventilation.
- Set the gas valve switch to ON.
If the unit shows an error code, look it up: Trane Furnace codes
More commissioning tips for furnace
Source: Trane 18-CD29D1-11 installer's guide, p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.