Trane Furnace: Carbon monoxide detectors and signage for Massachusetts side-wall venting
Carbon monoxide detectors and signage for Massachusetts side-wall venting on a Trane furnace: Side-wall horizontal venting where the exhaust terminal is under 7 ft above grade needs CO detectors and signage.
Applies to: Side-wall horizontal venting in Massachusetts
How to fix carbon monoxide detectors and signage for massachusetts side-wall venting: step by step
- Confirm a hard-wired CO detector with alarm and battery backup is installed on the floor level where the appliance is installed.
- Confirm a battery or hard-wired CO detector with alarm is installed on each additional level served.
- If the appliance is in a crawl space or attic, the detector may go on the next adjacent floor level.
- If the detectors cannot be completed at install, allow 30 days for the owner to comply, with a battery-operated CO detector installed in the meantime.
- Install a metal or plastic sign at least 8 ft above grade directly in line with the exhaust terminal, with lettering at least 1/2 in high that reads: GAS VENT DIRECTLY BELOW, KEEP CLEAR OF ALL OBSTRUCTIONS.
- Leave the venting kit installation instructions with the appliance when BAYAIR30AVENTA or BAYVENT200B is used.
If the unit shows an error code, look it up: Trane Furnace codes
Models
UH1B040A9241AUH1B060A9361AUH1B080A9421BUH1C080A9601AUH1C100A9481AUH1D100A9601AUH1D120A9601A
Source: Trane installer's guide, p. 25-29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.