Trane Furnace: Furnace in attic or crawl space (horizontal)
Furnace in attic or crawl space (horizontal) on a Trane furnace: Placement rules for a horizontal furnace in an attic or crawl space. Mostly about clearances, access and keeping the unit dry and supported.
Applies to: Horizontal UH1/DH1 furnaces
Common causes of furnace in attic or crawl space (horizontal)
- Horizontal furnace going into an attic, where service access and framing contact matter
- Horizontal furnace in a crawl space where moisture is a concern
- Suspended installs hung from joists or rafters
- Replacement jobs where the old platform is too small or in the wrong place
How to fix furnace in attic or crawl space (horizontal): step by step
- In an attic, place the furnace on the left side (as viewed from front in vertical position)
- Build a service platform large enough for clearances on all sides and front service access, because a tech has to reach the blower and burners
- Make sure only line contact occurs between the furnace casing edges and joists, studs or framing
- In a crawl space, set the furnace on a pad or noncombustible material to keep it dry
- If suspended, use 3/8 in all-thread rods with angle iron at both ends and the midpoint
- Make the angle iron at least 32 in long so panels can be reached
- Check the finished install for clearance to combustibles per the rating plate
If the unit shows an error code, look it up: Trane Furnace codes
Models
DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601
Source: Trane installer's guide 18-CD29D1-11, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.