Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Error Code 79: Water leakage detected (Tankless)

Updated · by Aurora Star Tech Inc.

Rinnai error code 79 on a tankless water heater means: Water leakage detected. It is also called Rinnai diagnostic code 79.

High severityTankless Water HeaterNon-SENSEI · RH180 hybrid

Homeowner? What Rinnai code 79 means for you

Call a technician Your tankless water heater is reporting: Water leakage detected. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code 79 mean?

The internal leak detector has sensed water inside the cabinet, or the leak sensor/its wiring is faulty.

Applies to: Non-SENSEI Series

Common causes of Rinnai code 79

  • Leaking heat exchanger or internal piping
  • Water pooled on the cabinet bottom pan
  • Wet leak sensor

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code 79

Show all 59 models

C199eC199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUS65eRUS75eV53DeV53eV65eV65iV75eV75iV94eV94iV94Xi

Other Rinnai Tankless codes

CodeMeaning
65Water flow control device (servo) fault
66Bypass flow servo fault
70PC board fault
71Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)
72Flame rod fault
73Burner thermocouple fault
FEFlammable vapors detected
FFMaintenance performed (history marker)
LCScale build-up in heat exchanger (LC, LC0–LC9, 00)
SECascade diagnostic display (error on secondary unit)
SEtInitial settings not yet confirmed
SSService Soon alert (also listed as 55)

All Rinnai Tankless Water Heater error codes →

Rinnai code 79: homeowner questions

What does Rinnai code 79 mean?

Water leakage detected. The internal leak detector has sensed water inside the cabinet, or the leak sensor/its wiring is faulty.

Is it safe to keep using my tankless water heater with code 79?

It depends on the cause. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Rinnai code 79 myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code 79 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code 79 near me?

Aurora Star Tech Inc. repairs Rinnai tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.62. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service