CodeMeaningSeverity
03Power interrupted during bath fillLow
05Bypass flow control device faultMedium
10Air supply or exhaust blocked / condensate trap fullCritical
11No ignitionHigh
11 (VA, VB, VC, KA, RH-180, KCM alternate checks)Code 11 - alternate checks for VA, VB, VC, KA, RH-180 and KCMHigh
12Flame failureHigh
14Thermal fuse or overheat sensor trippedCritical
15Venturi control faultHigh
16Outlet water over-temperature safety shutdownCritical
17Venturi blockageHigh
19Electrical grounding / DC circuit shortHigh
21PC board data transfer errorHigh
25Condensate pump failure or clogged drainMedium
32Outlet water temperature thermistor faultMedium
33Heat exchanger thermistor faultMedium
38Exhaust gas temperature sensor (CO sensor on RH180)Critical
41Freeze protection / outdoor air temperature sensor faultMedium
51Inlet water temperature thermistor faultMedium
52Gas valve / modulating solenoid valve (POV) signal faultHigh
54High exhaust gas temperatureCritical
61Combustion fan motor faultHigh
63Recirculation low flowMedium
65Water flow control device (servo) faultMedium
70PC board faultHigh
71Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)High
72Flame rod faultHigh
Diag historyMaintenance code history viewer (last 9 codes)Low
EVenturi reset sequence: step E (code 17 or 52 only)Low
ECLReset completeLow
FVenturi reset sequence: step FLow
FFMaintenance performed (history marker)Low
In Use fast flashIn Use light rapid flashLow
In Use slow flashIn Use light slow flashLow
In Use solidIn Use light steadyLow
LC, LC0-LC9Code LC, LC0-LC9Low
Lock keyController locked (key symbol)Low
MuteController key beeps on/offLow
Parameter modeParameter settings menuLow
Perf dataPerformance data viewer (live readings and counters)Low
Priority lightPriority light on (this controller is in charge)Low
SVenturi reset sequence: step S (SENSEI)Low
SECascade diagnostic display (error on secondary unit)Medium
SSService Soon alert (also listed as 55)Low
SS (55)Code SS (55)Low
tVenturi reset sequence: step tLow
Water flow fault (no code displayed)No-code water flow faultMedium
°C/°FTemperature scale switch (Celsius / Fahrenheit)Low

Troubleshooting the RSC199e

Rinnai RSC199e specs and setup data

All Rinnai Tankless Water Heater error codes →

Homeowner help: Tankless Water Heater No Hot Water: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.