Rinnai Error Code 11: No ignition (Wall Furnace)
Rinnai error code 11 on a wall furnace means: No ignition. It is also called Rinnai diagnostic code 11.
Homeowner? What Rinnai code 11 means for you
Call a technician Your wall furnace is reporting: No ignition. The wall furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 11 mean?
The burner did not light. Code 11 shows as a dim flashing number. The furnace retries ignition after 1 hour; the code clears after a successful ignition and is not kept in the fault history.
Applies to: Rinnai EnergySaver direct vent wall furnaces EX08DT, EX11DT, EX17DT, EX22DT
Common causes of Rinnai code 11
- Gas supply turned off
- Vent termination blocked
- Repeated ignition failure needing service
Rinnai models that use code 11
EX08DTEX11DTEX17DTEX22DTEX22DT-W
Other Rinnai Wall Furnace codes
All Rinnai Wall Furnace error codes →
Rinnai code 11: homeowner questions
What does Rinnai code 11 mean?
No ignition. The burner did not light. Code 11 shows as a dim flashing number. The furnace retries ignition after 1 hour; the code clears after a successful ignition and is not kept in the fault history.
Is it safe to keep using my wall furnace with code 11?
It depends on the cause. The wall furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rinnai code 11 myself?
You can try one reset (power off for 30 seconds, then on). If Rinnai code 11 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rinnai code 11 near me?
Aurora Star Tech Inc. repairs Rinnai wall furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check
Troubleshooting guides
- Lock or unlock the control panel Rinnai · Wall Furnace
- Select remote thermostat mode (01) or control panel mode (02) Rinnai · Wall Furnace
- Select the gas code (gas type, altitude, vent length) Rinnai · Wall Furnace
- Set low and high fire gas pressure with the Test Switch Rinnai · Wall Furnace
- Switch the display between Fahrenheit and Celsius Rinnai · Wall Furnace
- Turn Set back (frost protection) on or off Rinnai · Wall Furnace
Source: Rinnai EX08DT/EX11DT and EX17DT/EX22DT Installation and Operation Manuals (200000083, 200000084), Table 9 'Diagnostic Codes', p.35–36. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.