Rinnai Error Code 170: Venturi blockage / position mismatch (Combi Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code 170 on a combi boiler means: Venturi blockage / position mismatch. It is also called Rinnai diagnostic code 170.

High severityCombi BoilerI-Series Plus 150K and smaller · I-Series Plus 175K and higher

Homeowner? What Rinnai code 170 means for you

Call a technician Your combi boiler is reporting: Venturi blockage / position mismatch. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
  • If only hot water is missing, check that the hot water tap is open far enough to start the heater.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code 170 mean?

The venturi position detected doesn't match the value calculated and stored in the PC Board memory.

Applies to: I-Series Plus boilers — 150K BTU and smaller and 175K BTU and higher (Combi and Solo)

Common causes of Rinnai code 170

  • Obstructed intake, exhaust chamber or vent termination
  • Debris build-up in the venturi
  • Clogged condensate trap

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code 170

IP060160CIP090099CIP090160CIP090199CIP120199CIP150199CIP175199CIP199199C

Other Rinnai Combi Boiler codes

CodeMeaning
100Air intake/exhaust blockage or full condensate trap
110Ignition failure
120Flame failure (flame lost during operation)
140Overheat switch tripped (heat exchanger overheating)
150Venturi control fault
161High DHW outgoing water temperature
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error
220Gas valve position not detected (reed switch)
250Condensate pump switch tripped (accessory)
303Secondary system thermistor fault

All Rinnai Combi Boiler error codes →

Rinnai code 170: homeowner questions

What does Rinnai code 170 mean?

Venturi blockage / position mismatch. The venturi position detected doesn't match the value calculated and stored in the PC Board memory.

Is it safe to keep using my combi boiler with code 170?

It depends on the cause. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Rinnai code 170 myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code 170 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code 170 near me?

Aurora Star Tech Inc. repairs Rinnai combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Source: Rinnai Troubleshooting I-Series Plus Boiler Diagnostic Codes (800000375), p.12–13. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.