Rinnai Error Code 140: Overheat switch tripped (heat exchanger overheating) (Combi Boiler)
Rinnai error code 140 on a combi boiler means: Overheat switch tripped (heat exchanger overheating). It is also called Rinnai diagnostic code 140.
Homeowner? What Rinnai code 140 means for you
Stop and call Your combi boiler is reporting: Overheat switch tripped (heat exchanger overheating). This code is a safety shutdown. Turn the combi boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 140 mean?
The bi-metal overheat switch on the right side of the heat exchanger has opened, indicating overheating. It self-resets once cool but will keep tripping until the root cause is fixed.
Applies to: I-Series Plus boilers — 150K BTU and smaller and 175K BTU and higher (Combi and Solo)
Common causes of Rinnai code 140
- Air in the system (incomplete deaeration)
- Boiler pump not running, miswired, reversed or seized; blown fuse
- Closed valves, frozen CH circuit or indirect tank pump issue
A technician checks these and 4 other possible causes on site before replacing any part.
Rinnai models that use code 140
IP060160CIP090099CIP090160CIP090199CIP120199CIP150199CIP175199CIP199199C
Other Rinnai Combi Boiler codes
All Rinnai Combi Boiler error codes →
Rinnai code 140: homeowner questions
What does Rinnai code 140 mean?
Overheat switch tripped (heat exchanger overheating). The bi-metal overheat switch on the right side of the heat exchanger has opened, indicating overheating. It self-resets once cool but will keep tripping until the root cause is fixed.
Is it safe to keep using my combi boiler with code 140?
No. Code 140 is a safety shutdown, so keep the combi boiler off until a licensed technician has checked it.
Can I reset Rinnai code 140 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Rinnai code 140 near me?
Aurora Star Tech Inc. repairs Rinnai combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check
Troubleshooting guides
- Open the parameter settings menu on the PC board Rinnai · Combi Boiler
- Replacement gas valve assembly comes with a propane orifice Rinnai · Combi Boiler
- Vent termination near an openable window or door (Canada, TB-200) Rinnai · Combi Boiler
- Venturi reset on the PC board (code 170) Rinnai · Combi Boiler
- View the last nine error codes (DHW + Up) Rinnai · Combi Boiler
Source: Rinnai Troubleshooting I-Series Plus Boiler Diagnostic Codes (800000375), p.9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.