Rinnai Error Code H: Set temperature H (maximum burner output) (Wall Furnace)

Updated · by Aurora Star Tech Inc.

Rinnai error code H on a wall furnace means: Set temperature H (maximum burner output). It is also called Rinnai diagnostic code H.

Low severityWall FurnaceEX DT

Homeowner? What Rinnai code H means for you

Usually minor Your wall furnace is reporting: Set temperature H (maximum burner output). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code H mean?

On the set-temperature display, H is the highest setting, where the burner runs at maximum combustion.

Applies to: Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code H

EX08DTEX11DTEX17DTEX22DTEX22DT-W

Other Rinnai Wall Furnace codes

CodeMeaning
72Flame rod failure
73Communication error
99Flue blocked
A1-A8 / L1-L8Gas code selection (gas type, altitude, vent length)
EconomyEconomy indicator lit
FILTERFilter lamp flashing red (air filter blocked)
LSet temperature L (minimum burner output)
LockControl panel lock indicator
ON lamp greenON indicator green (powered, burner not lit)
ON lamp redON indicator red (burner lit)
PHHigh-fire gas pressure setting mode
PLLow-fire gas pressure setting mode

All Rinnai Wall Furnace error codes →

Rinnai code H: homeowner questions

What does Rinnai code H mean?

Set temperature H (maximum burner output). On the set-temperature display, H is the highest setting, where the burner runs at maximum combustion.

Is it safe to keep using my wall furnace with code H?

Usually yes. Code H is normally minor, but if it keeps coming back have it checked.

Can I reset Rinnai code H myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code H comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code H near me?

Aurora Star Tech Inc. repairs Rinnai wall furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check

Troubleshooting guides

Source: Rinnai EX08DT/EX11DT Installation and Operation Manual (200000083) and EX17DT/EX22DT (200000084), Thermostat p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.