Rinnai Error Code 52: Gas valve / modulating solenoid valve (POV) signal fault (Tankless)
Rinnai error code 52 on a tankless water heater means: Gas valve / modulating solenoid valve (POV) signal fault. It is also called Rinnai diagnostic code 52.
Homeowner? What Rinnai code 52 means for you
Call a technician Your tankless water heater is reporting: Gas valve / modulating solenoid valve (POV) signal fault. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
- Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the hot and cold water valves under the heater are fully open.
- If you have a remote controller, turn it off and on once. If the code comes back, call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 52 mean?
Fault in the gas valve circuit. On SENSEI and SENSEI RX/CX units it involves the gas valve solenoid; on Non-SENSEI units it means the modulating solenoid valve (POV) signal is abnormal.
Applies to: SENSEI Series, SENSEI RX/CX Series, Non-SENSEI Series
Common causes of Rinnai code 52
- Loose, broken or damaged flame rod or flame rod wiring
- Loose or damaged terminals on the gas solenoid harness
- Failed gas valve solenoid or gas valve/venturi assembly
A technician checks these and 3 other possible causes on site before replacing any part.
Rinnai models that use code 52
Show all 97 models
C199eC199iCU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU80eRU80iRU90eRU98eRU98iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUR160eRUR160iRUR199eRUR199iRUS65eRUS75eRX130iRX160iRX180iRX199iRXP160iRXP199iV53DeV53eV65eV65iV75eV75iV94eV94iV94XiVE140eVE140iVE160eVE160iVE180eVE180iVE199eVE199i
Other Rinnai Tankless codes
All Rinnai Tankless Water Heater error codes →
Rinnai code 52: homeowner questions
What does Rinnai code 52 mean?
Gas valve / modulating solenoid valve (POV) signal fault. Fault in the gas valve circuit. On SENSEI and SENSEI RX/CX units it involves the gas valve solenoid; on Non-SENSEI units it means the modulating solenoid valve (POV) signal is abnormal.
Is it safe to keep using my tankless water heater with code 52?
It depends on the cause. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rinnai code 52 myself?
You can try one reset (power off for 30 seconds, then on). If Rinnai code 52 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rinnai code 52 near me?
Aurora Star Tech Inc. repairs Rinnai tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Tankless Water Heater No Hot Water: What to Check
Troubleshooting guides
- No hot water All brands · Tankless Water Heater
- Water temperature fluctuates All brands · Tankless Water Heater
- Alternate piping arrangements Rinnai · Tankless Water Heater
- Balance hot water risers after install Rinnai · Tankless Water Heater
- BMS Gateway: building system cannot talk to the gateway Rinnai · Tankless Water Heater
- BMS Gateway: cannot log in to the setup screens Rinnai · Tankless Water Heater
- BMS Gateway: gateway cannot see the tankless heaters Rinnai · Tankless Water Heater
- BMS Gateway: reset IP address and admin password to default Rinnai · Tankless Water Heater
Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.46–48. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.