Rinnai Error Code Parameter mode: Parameter settings menu (Tankless)

Updated · by Aurora Star Tech Inc.

Rinnai error code Parameter mode on a tankless water heater means: Parameter settings menu. It is also called Rinnai diagnostic code Parameter mode.

Low severityTankless Water HeaterSENSEI RX/CX · SENSEI

Homeowner? What Rinnai code Parameter mode means for you

Usually minor Your tankless water heater is reporting: Parameter settings menu. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code Parameter mode mean?

Installer menu used to change the heater's parameter settings with the A and B pushbuttons on the PC board together with the controller keys. The controller shows the setting number with its choice letter, for example 01A changing to 01b. Do not change parameters unless an instruction calls for it. On RX/CX the gas-type parameter (10) can only be changed within 20 minutes after power is supplied.

Applies to: Rinnai SENSEI tankless (RU, RUR, RSC, CU) and SENSEI RX/CX (RX, RXP, CX, CXP)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code Parameter mode

Show all 30 models

CU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRUR160eRUR160iRUR199eRUR199iRX130iRX160iRX180iRX199iRXP160iRXP199i

Other Rinnai Tankless codes

CodeMeaning
LPGInitial setting: propane (LPG)
Maint monitorKCM maintenance monitor (flow and outlet temperature)
MuteController key beeps on/off
nGInitial setting: natural gas
ONHot water running (controller installed)
OutInitial setting: outdoor installation
Parameter settingsParameter (installer settings) mode
Perf dataPerformance data viewer (live readings and counters)
Performance dataPerformance data readout mode
Priority lightPriority light on (this controller is in charge)
rnSDescaling finished, rinse now
SVenturi reset sequence: step S (SENSEI)

All Rinnai Tankless Water Heater error codes →

Rinnai code Parameter mode: homeowner questions

What does Rinnai code Parameter mode mean?

Parameter settings menu. Installer menu used to change the heater's parameter settings with the A and B pushbuttons on the PC board together with the controller keys. The controller shows the setting number with its choice letter, for example 01A changing to 01b.…

Is it safe to keep using my tankless water heater with code Parameter mode?

Usually yes. Code Parameter mode is normally minor, but if it keeps coming back have it checked.

Can I reset Rinnai code Parameter mode myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code Parameter mode comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code Parameter mode near me?

Aurora Star Tech Inc. repairs Rinnai tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Rinnai N-Series Residential (100000467) / with Pump (100000508) / Commercial (100000504) / RSC SENSEI (100000773) Installation and Operation Manuals, 4.12 Configure Parameter Settings p.61; Rinnai SENSEI RX Residential Installation and Operation Manual (100000839), 4.13 p.48. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.