Rinnai EX22DT error codes list

CodeMeaningSeverity
00Control mode setting 00 (factory default)Low
01Control mode setting 01 (remote thermostat mode)Low
02Control mode setting 02 (control panel mode)Low
11No ignitionHigh
14Overheat (fusible link)Critical
16Room overheat (above 104°F / 40°C)Medium
30Overheat temperature thermistor 2 open circuitMedium
31Room temperature thermistor open circuitMedium
32Room temperature thermistor short circuitMedium
33Overheat thermistor 1 open circuitMedium
34Overheat thermistor 1 short circuitMedium
35Overheat temperature thermistor 2 short circuitMedium
40Pressure sensor sensing tube failureMedium
49Pressure sensor breakdownMedium
53Abnormal spark sensedMedium
61Combustion fan faultMedium
62Convection fan faultMedium
70ON/OFF or Set Back switch faultMedium
71Solenoid valve failureMedium
72Flame rod failureMedium
73Communication errorMedium
99Flue blockedCritical
A1-A8 / L1-L8Gas code selection (gas type, altitude, vent length)Low
EconomyEconomy indicator litLow
FILTERFilter lamp flashing red (air filter blocked)Low
HSet temperature H (maximum burner output)Low
LSet temperature L (minimum burner output)Low
LockControl panel lock indicatorLow
ON lamp greenON indicator green (powered, burner not lit)Low
ON lamp redON indicator red (burner lit)Low
PHHigh-fire gas pressure setting modeLow
PLLow-fire gas pressure setting modeLow
Set / Room tempDisplay: set temperature and room temperatureLow
Set backSet back indicator lit (frost protection on)Low
Timer lampTimer lamp solid or flashingLow
°F/°CTemperature scale selectionLow

Troubleshooting the EX22DT

Rinnai EX22DT specs and setup data

All Rinnai Wall Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.