CodeMeaningSeverity
(blank)Status monitor: standbyLow
--Status monitor: power just connectedLow
1Hot water running, no controller: 120°F settingLow
02Burner did not operate during freeze protectionHigh
2Hot water running, no controller: 125°F settingLow
03Power interrupted during bath fillLow
3Hot water running, no controller: 135°F settingLow
4Hot water running, no controller: 140°F settingLow
05Bypass flow control device faultMedium
07Circulation flow rate below 2.1 GPMMedium
10Air supply or exhaust blocked / condensate trap fullCritical
11No ignitionHigh
11 (VA, VB, VC, KA, RH-180, KCM alternate checks)Code 11 - alternate checks for VA, VB, VC, KA, RH-180 and KCMHigh
12Flame failureHigh
13Combustion faultCritical
14Thermal fuse or overheat sensor trippedCritical
15Venturi control faultHigh
16Outlet water over-temperature safety shutdownCritical
17Venturi blockageHigh
18Gas valve air/fuel adjustment limit reachedHigh
19Electrical grounding / DC circuit shortHigh
21PC board data transfer errorHigh
22Gas valve adjustment faultMedium
25Condensate pump failure or clogged drainMedium
30Flammable vapor sensor activated or faultyCritical
31Burner thermocouple out of rangeHigh
32Outlet water temperature thermistor faultMedium
33Heat exchanger thermistor faultMedium
34Combustion air thermistor (Non-SENSEI) / Lime detecting thermistor (RX/CX)Medium
35Tank temperature sensor faultMedium
38Exhaust gas temperature sensor (CO sensor on RH180)Critical
41Freeze protection / outdoor air temperature sensor faultMedium
51Inlet water temperature thermistor faultMedium
52Gas valve / modulating solenoid valve (POV) signal faultHigh
54High exhaust gas temperatureCritical
57Burner overheat bi-metal switch openCritical
58Secondary heat exchanger bi-metal switch openHigh
60Descaling countdown (minutes left)Low
61Combustion fan motor faultHigh
63Recirculation low flowMedium
65Water flow control device (servo) faultMedium
66Bypass flow servo faultMedium
70PC board faultHigh
71Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)High
72Flame rod faultHigh
73Burner thermocouple faultHigh
79Water leakage detectedHigh
888Initial settings savedLow
AVenturi reset sequence: step A (RX/CX)Low
AdJVenturi reset sequence: step AdJ (RX/CX)Low
Bluetooth LED blinkingBluetooth LED blinking (push-button pairing mode)Low
Bluetooth LED solidBluetooth LED solid blue (app pairing mode)Low
dESDescaling (flush) modeLow
Diag historyMaintenance code history viewer (last 9 codes)Low
Diagnostic historyShow last 9 maintenance codesLow
EVenturi reset sequence: step E (code 17 or 52 only)Low
ECLReset completeLow
EndDescaling procedure endedLow
FVenturi reset sequence: step FLow
FEFlammable vapors detectedCritical
FFMaintenance performed (history marker)Low
FHForced high-fire combustionLow
FLForced low-fire combustionLow
InInitial setting: indoor installationLow
In Use fast flashIn Use light rapid flashLow
In Use slow flashIn Use light slow flashLow
In Use solidIn Use light steadyLow
LCScale build-up in heat exchanger (LC, LC0–LC9, 00)Medium
LC, LC0-LC9Code LC, LC0-LC9Low
LOCController locked (KCM)Low
Lock keyController locked (key symbol)Low
LPGInitial setting: propane (LPG)Low
Maint monitorKCM maintenance monitor (flow and outlet temperature)Low
MuteController key beeps on/offLow
nGInitial setting: natural gasLow
ONHot water running (controller installed)Low
OutInitial setting: outdoor installationLow
Parameter modeParameter settings menuLow
Parameter settingsParameter (installer settings) modeLow
Perf dataPerformance data viewer (live readings and counters)Low
Performance dataPerformance data readout modeLow
Priority lightPriority light on (this controller is in charge)Low
rnSDescaling finished, rinse nowLow
SVenturi reset sequence: step S (SENSEI)Low
SECascade diagnostic display (error on secondary unit)Medium
SEtInitial settings not yet confirmedLow
SSService Soon alert (also listed as 55)Low
SS (55)Code SS (55)Low
tVenturi reset sequence: step tLow
Water flow fault (no code displayed)No-code water flow faultMedium
°C/°FTemperature scale switch (Celsius / Fahrenheit)Low

Find codes by Rinnai model

Non-SENSEI

C199eC199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUS65eRUS75eV53DeV53eV65eV65iV75eV75iV94eV94iV94XiVE140eVE140iVE160eVE160iVE180eVE180iVE199eVE199i

SENSEI

CU160eCU160iCU199eCU199iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRUR160eRUR160iRUR199eRUR199i

SENSEI RX/CX

CX160iCX199iCXP160iCXP199iRX130iRX160iRX180iRX199iRXP160iRXP199i

RH180 hybrid

RH180

Tankless Water Heater troubleshooting guides

Rinnai Tankless Water Heater specs and setup data

Homeowner help: Tankless Water Heater No Hot Water: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977