Rinnai Error Code 17: Venturi blockage (Tankless)
Rinnai error code 17 on a tankless water heater means: Venturi blockage. It is also called Rinnai diagnostic code 17.
Homeowner? What Rinnai code 17 means for you
Call a technician Your tankless water heater is reporting: Venturi blockage. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
- Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the hot and cold water valves under the heater are fully open.
- If you have a remote controller, turn it off and on once. If the code comes back, call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 17 mean?
The unit has detected a blocked venturi or restricted air path; after cleaning, a manual reset sequence on the PC board is needed to return to normal operation.
Applies to: SENSEI Series; SENSEI RX/CX Series
Common causes of Rinnai code 17
- Condensate drain line not draining
- Obstruction in intake, exhaust chamber or vent termination
- Debris build-up in the venturi assembly
Rinnai models that use code 17
Show all 30 models
CU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRUR160eRUR160iRUR199eRUR199iRX130iRX160iRX180iRX199iRXP160iRXP199i
Other Rinnai Tankless codes
All Rinnai Tankless Water Heater error codes →
Rinnai code 17: homeowner questions
What does Rinnai code 17 mean?
Venturi blockage. The unit has detected a blocked venturi or restricted air path; after cleaning, a manual reset sequence on the PC board is needed to return to normal operation.
Is it safe to keep using my tankless water heater with code 17?
It depends on the cause. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rinnai code 17 myself?
You can try one reset (power off for 30 seconds, then on). If Rinnai code 17 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rinnai code 17 near me?
Aurora Star Tech Inc. repairs Rinnai tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Tankless Water Heater No Hot Water: What to Check
Troubleshooting guides
- No hot water All brands · Tankless Water Heater
- Water temperature fluctuates All brands · Tankless Water Heater
- Alternate piping arrangements Rinnai · Tankless Water Heater
- Balance hot water risers after install Rinnai · Tankless Water Heater
- BMS Gateway: building system cannot talk to the gateway Rinnai · Tankless Water Heater
- BMS Gateway: cannot log in to the setup screens Rinnai · Tankless Water Heater
- BMS Gateway: gateway cannot see the tankless heaters Rinnai · Tankless Water Heater
- BMS Gateway: reset IP address and admin password to default Rinnai · Tankless Water Heater
Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.28–29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.