Carrier Error Code 13: Limit circuit lockout (Furnace)
Carrier error code 13 on a furnace means: Limit circuit lockout. It is also called Carrier diagnostic code 13.
Homeowner? What Carrier code 13 means for you
Stop and call Your furnace is reporting: Limit circuit lockout. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Carrier error code 13 mean?
Lockout because the limit or flame rollout switch stayed open more than 3 minutes, or there were 10 successive limit trips in high heat. Auto-resets after 3 hours.
Applies to: 59TP6A two-stage variable-speed ECM multipoise condensing gas furnace, all sizes (040-10 to 120-22)
Common causes of Carrier code 13
- Dirty filter or restricted ductwork
- Loose blower wheel
- Wrong low- or high-heat gas input
A technician checks these and 3 other possible causes on site before replacing any part.
Carrier models that use code 13
Show all 22 models
58SB0A045E14--1258SB0A045E17--1258SB0A070E14--1258SB0A070E17--1258SB0A070E17--1658SB0A070E21--1658SB0A090E17--1458SB0A090E21--1658SB0A090E21--2058SB0A090E24--2058SB0A110E21--2058SB0A110E24--2058SB0A135E24--2058SB0A155E24--2059TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22
Other Carrier Furnace codes
All Carrier Furnace error codes →
Carrier code 13: homeowner questions
What does Carrier code 13 mean?
Limit circuit lockout. Lockout because the limit or flame rollout switch stayed open more than 3 minutes, or there were 10 successive limit trips in high heat. Auto-resets after 3 hours.
Is it safe to keep using my furnace with code 13?
No. Code 13 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.
Can I reset Carrier code 13 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Carrier code 13 near me?
Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Carrier 59TP6A Installation, Start-up, Operating and Service Instructions, Fig. 66 Troubleshooting Guide, p.88. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.