Carrier DLCMRBH18BAK Error Codes

Updated · by Aurora Star Tech Inc.

Carrier DLCMRBH18BAK error codes and diagnostic codes (also listed as sold as Viessmann Vitocal 200-S, 18K 2 zone). The DLCMRBH18BAK is a Carrier mini-split in the Carrier DLCM(R/H)B multi-zone outdoor series.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Carrier DLCMRBH18BAK error codes list

CodeMeaningSeverity
dFDefrostLow
E1Indoor / outdoor communication errorHigh
EC07Outdoor fan speed out of rangeHigh
EC50Outdoor temperature sensor faultMedium
EC51Outdoor EEPROM errorHigh
EC52Condenser coil sensor (T3) faultMedium
EC53Outdoor ambient sensor (T4) faultMedium
EC54Discharge temperature sensor (TP/T5) faultMedium
EC55IPM temperature sensor faultMedium
EC56Indoor coil outlet sensor (T2B) faultMedium
EC57Refrigerant pipe sensor faultMedium
EC71Outdoor fan motor over-currentHigh
EC72Outdoor fan motor phase lossHigh
EL01Indoor / outdoor communication errorHigh
F0Current overload protectionHigh
F1Outdoor ambient sensor (T4) faultMedium
F2Condenser coil sensor (T3) faultMedium
F3Discharge sensor (T5) faultMedium
F4Outdoor EEPROM errorHigh
F5Outdoor fan speed out of controlHigh
FbVapor injection inlet sensor faultMedium
FCForced coolingLow
FdVapor injection outlet sensor faultMedium
FL14Indoor and outdoor units not compatibleMedium
J0Outdoor coil overheat in coolingMedium
J1Indoor coil temperature protection in heatingMedium
J2Discharge temperature protectionHigh
J3PFC module protectionHigh
J4Main board to IPM board communication errorHigh
J5High pressure protectionHigh
J6Low pressure protectionHigh
J8AC voltage protectionHigh
LC06IPM high temperature / PFC frequency limitMedium
ODU --Outdoor board standbyLow
ODU 00Wiring / piping check finishedLow
ODU CEAutomatic wiring / piping check runningLow
ODU E0Outdoor EEPROM error (outdoor board)High
ODU E2Indoor / outdoor communication error (outdoor board)High
ODU E3IPM to main board communication error (outdoor board)High
ODU E4Outdoor or T2B sensor fault (outdoor board)Medium
ODU E5Over or under voltage (outdoor board)High
ODU E6PFC module protection (outdoor board)High
ODU E8Outdoor fan speed fault (outdoor board)High
ODU EdAdapter / inverter board to main board communication errorHigh
ODU F1Zone A coil outlet sensor (T2B-A) faultMedium
ODU F2Zone B coil outlet sensor (T2B-B) faultMedium
ODU F3Zone C coil outlet sensor (T2B-C) faultMedium
ODU F4Zone D coil outlet sensor (T2B-D) faultMedium
ODU F5Zone E coil outlet sensor (T2B-E) faultMedium
ODU F6Zone F coil outlet sensor (T2B-F) faultMedium
ODU Hz readoutCompressor running frequencyLow
ODU LCLow ambient cooling modeLow
ODU LPLow outdoor temperature protection (outdoor board)Low
ODU P0Compressor top overheat (outdoor board)High
ODU P1High pressure protection (outdoor board)High
ODU P2Low pressure protection (outdoor board)High
ODU P3Current overload (outdoor board)High
ODU P4Discharge temperature protection (outdoor board)High
ODU P5Condenser high temperature (outdoor board)Medium
ODU P6Inverter module (IPM) fault (outdoor board)Critical
ODU PHCompressor pre-heatLow
ODU ROOil return cycleLow
P0Inverter module (IPM) faultCritical
P1Over or under voltage protectionHigh
P2Compressor top overheat (OLP)High
P3Low outdoor temperature cut-off in heatingLow
P4Compressor drive faultHigh
P7IPM temperature sensor faultMedium
PC0ACondenser high temperature protectionMedium
PC0FPFC module protectionHigh
PC0LOutdoor temperature too lowLow
PC00Inverter module (IPM) protectionCritical
PC02Compressor top overheat (OLP)High
PC06Discharge temperature protectionHigh
PC08Outdoor over-current protectionHigh
PC10Low AC supply voltageHigh
PC11AC supply voltage protection (over voltage)High
PC12DC bus high voltage / 341 MCE errorHigh
PC30High pressure protectionHigh
PC31Low pressure protectionHigh
PC40Main chip to compressor drive chip communication errorHigh
PC42Compressor start failureHigh
PC43Compressor phase lossHigh
PC44Zero speed protectionHigh
PC45Compressor drive chip (IR / 341 PWM) failureHigh
PC46Compressor speed out of controlHigh
PC49Compressor over-currentHigh
PCA1Refrigerant pipe condensation protectionLow
PH90Evaporator coil too hotMedium
PH91Evaporator coil too coldMedium

Troubleshooting the DLCMRBH18BAK

All Carrier Mini-Split error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.