Carrier Error Code EH00: Indoor EEPROM error (Mini-Split)
Carrier error code EH00 on a mini-split means: Indoor EEPROM error. It is also called Carrier diagnostic code EH00.
Homeowner? What Carrier code EH00 means for you
Call a technician Your ductless mini-split is reporting: Indoor EEPROM error. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
- Check the breaker and the outdoor disconnect; both should be ON.
- Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
- Keep the outdoor unit clear of snow, ice and leaves.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Carrier error code EH00 mean?
The indoor main chip gets no answer from its EEPROM chip. Also shown as EH0A.
Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units
Common causes of Carrier code EH00
- Bad indoor PCB
Carrier models that use code EH00
DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK
Other Carrier Mini-Split codes
All Carrier Mini-Split error codes →
Carrier code EH00: homeowner questions
What does Carrier code EH00 mean?
Indoor EEPROM error. The indoor main chip gets no answer from its EEPROM chip. Also shown as EH0A.
Is it safe to keep using my ductless mini-split with code EH00?
It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Carrier code EH00 myself?
You can try one reset (power off for 30 seconds, then on). If Carrier code EH00 comes back, the cause is still there and a licensed technician should check it.
Who can fix Carrier code EH00 near me?
Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Indoor unit leaking water All brands · Mini-Split
- Poor capacity / high head All brands · Mini-Split
- Water leaking All brands · Mini-Split
- Discharge the inverter capacitors before service Carrier · Mini-Split
- Display shows a strange code or does not answer the remote - DLFSHB indoor Carrier · Mini-Split
- Multi-zone: one room heats, another will not cool - DLC multi-zone Carrier · Mini-Split
- Read live data with the outdoor check button (SW1) Carrier · Mini-Split
- Run the automatic wiring / piping correction Carrier · Mini-Split
Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17, p.25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.