Carrier Error Code PC 0L: Low ambient temperature protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code PC 0L on a mini-split means: Low ambient temperature protection. It is also called Carrier diagnostic code PC 0L.

Low severityMini-SplitD5FCFA

Homeowner? What Carrier code PC 0L means for you

Usually minor Your ductless mini-split is reporting: Low ambient temperature protection. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code PC 0L mean?

A protection function. With the compressor off, the stop occurs when outdoor ambient (T4) is below -35 °C for 10 s. With the compressor on, the stop occurs when T4 is below -40 °C for 10 s. The unit exits protection when T4 is no lower than -32 °C for 10 s.

Applies to: D5FCFAH console ductless system, sizes 18K to 60K

Common causes of Carrier code PC 0L

  • Outdoor ambient temperature too low
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code PC 0L

D5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA

Other Carrier Mini-Split codes

CodeMeaning
P7IPM temperature sensor fault
PC0ACondenser high temperature protection
PC 0aError code PC 0a
PC0FPFC module protection
PC 0FError code PC 0F
PC0LOutdoor temperature too low
PC00Inverter module (IPM) protection
PC 00Error code PC 00
PC01ODU voltage protection
PC 01Outdoor voltage protection
PC02Compressor top overheat (OLP)
PC 02Error code PC 02

All Carrier Mini-Split error codes →

Carrier code PC 0L: homeowner questions

What does Carrier code PC 0L mean?

Low ambient temperature protection. A protection function. With the compressor off, the stop occurs when outdoor ambient (T4) is below -35 °C for 10 s. With the compressor on, the stop occurs when T4 is below -40 °C for 10 s. The unit exits protection when T4 is no lower…

Is it safe to keep using my ductless mini-split with code PC 0L?

Usually yes. Code PC 0L is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code PC 0L myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code PC 0L comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code PC 0L near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FCFAH service manual, p. 48. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977