Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code 15: Blower motor lockout (Furnace)

Updated · by Aurora Star Tech Inc.

Carrier error code 15 on a furnace means: Blower motor lockout. It is also called Carrier diagnostic code 15.

High severityFurnace59TP6A

Homeowner? What Carrier code 15 means for you

Call a technician Your furnace is reporting: Blower motor lockout. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code 15 mean?

The blower failed to reach 250 RPM, or did not communicate within 30 seconds after being turned on, in two heating cycles in a row. Auto-resets after 3 hours. This code comes from the troubleshooting guide; it is not printed on the blower-door service label.

Applies to: 59TP6A two-stage variable-speed ECM multipoise condensing gas furnace, all sizes (040-10 to 120-22)

Common causes of Carrier code 15

  • Blower motor (ECM) fault
  • Blower motor wiring or communication problem
  • Blower wheel obstruction
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code 15

59TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22

Other Carrier Furnace codes

CodeMeaning
13Limit circuit lockout
13.1Limit lockout - main limit open over 3 minutes
14Ignition lockout
14.1Ignition lockout after 4 tries
14.2Lockout - flame lost 3 times after 70 s of heating
14.3Lockout - 7 flame-loss events in one heat call
21Gas heating lockout
21.124 VAC on gas valve when it should be off
22Abnormal flame-proving signal
22.1False flame
23Pressure switch did not open
23.1Main pressure switch stuck closed

All Carrier Furnace error codes →

Carrier code 15: homeowner questions

What does Carrier code 15 mean?

Blower motor lockout. The blower failed to reach 250 RPM, or did not communicate within 30 seconds after being turned on, in two heating cycles in a row. Auto-resets after 3 hours. This code comes from the troubleshooting guide; it is not printed on the…

Is it safe to keep using my furnace with code 15?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code 15 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code 15 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code 15 near me?

Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Carrier 59TP6A Installation, Start-up, Operating and Service Instructions, Fig. 66 Troubleshooting Guide (cont.), p.89; Component Self-Test, p.77. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977