Carrier Error Code CL: Filter cleaning reminder / Active Clean (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code CL on a mini-split means: Filter cleaning reminder / Active Clean. It is also called Carrier diagnostic code CL.

Low severityMini-SplitCarrier DLFSHB high wall indoor

Homeowner? What Carrier code CL means for you

Usually minor Your ductless mini-split is reporting: Filter cleaning reminder / Active Clean. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code CL mean?

Reminder to clean the filter, or Active Clean running on models that have it.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code CL

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Carrier Mini-Split codes

CodeMeaning
--Indoor units mode conflict
APWi-Fi pairing (AP mode)
CPRemote switched off
d1Demand response signal DR1 received
d2Demand response signal DR2 received
d3Demand response signal DR3 received
dEDemand response input error
dFDefrost
E-C-OECO mode
E1Indoor / outdoor communication error
EC07Outdoor fan speed out of range
EC50Outdoor temperature sensor fault

All Carrier Mini-Split error codes →

Carrier code CL: homeowner questions

What does Carrier code CL mean?

Filter cleaning reminder / Active Clean. Reminder to clean the filter, or Active Clean running on models that have it.

Is it safe to keep using my ductless mini-split with code CL?

Usually yes. Code CL is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code CL myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code CL comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code CL near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Midea DLFSHBH09XAK indoor display table (photo, 2026-10-16); Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Display Function p.12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.