Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code Ht: Heating (59SC6A, 59MN7C menu: heating airflow setting) (Furnace)

Updated · by Aurora Star Tech Inc.

Carrier error code Ht on a furnace means: Heating (59SC6A, 59MN7C menu: heating airflow setting). It is also called Carrier diagnostic code Ht.

Low severityFurnace59SC6A · 59MN7C

Homeowner? What Carrier code Ht means for you

Usually minor Your furnace is reporting: Heating (59SC6A, 59MN7C menu: heating airflow setting). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code Ht mean?

On the 59SC6A the display shows Ht while gas heating is running. In the main menu on the 59SC6A and 59MN7C, Ht is the heating blower speed setting (higher number lowers temperature rise, lower number raises it). On the 59MN7C the status display for heating is shown as Ht with the firing rate (see Ht-%).

Applies to: 59SC6A and 59MN7C furnaces (3-digit display control)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code Ht

59MN7C060C17--1459MN7C060C21--2059MN7C080C17--1459MN7C080C21--2059MN7C100C21--2259MN7C120C24--2259SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22

Other Carrier Furnace codes

CodeMeaning
ErrComponent test could not start
FLtMenu: last 7 faults
FnComponent test - blower
HoDMenu: heat blower-off delay
HpdHeat pump defrost - furnace heating
HSiComponent test - hot surface igniter
Ht-%Heating at a percent firing rate (59MN7C)
Ht1Low-stage heating (PG96VTA)
Ht2High-stage heating (PG96VTA)
HttMenu: heating thermostat type
iDlIdle - standby, no demand
inFMenu: program number and software

All Carrier Furnace error codes →

Carrier code Ht: homeowner questions

What does Carrier code Ht mean?

Heating (59SC6A, 59MN7C menu: heating airflow setting). On the 59SC6A the display shows Ht while gas heating is running. In the main menu on the 59SC6A and 59MN7C, Ht is the heating blower speed setting (higher number lowers temperature rise, lower number raises it). On the 59MN7C the status…

Is it safe to keep using my furnace with code Ht?

Usually yes. Code Ht is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code Ht myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code Ht comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code Ht near me?

Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Carrier 59SC6A installation instructions, Table 20, p.52 and Table 21, p.53; Carrier 59MN7C installation instructions, Table 18 Main Menu Options, p.47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977