Carrier Furnace Error Codes

Updated · by Aurora Star Tech Inc.

50 Carrier Furnace error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Carrier Furnace error codes list

CodeMeaningSeverity
10.1L1 polarity faultHigh
11No previous codeLow
12Blower on after power-up (normal)Low
12.1W (heat call) on at power upLow
13Limit circuit lockoutCritical
13.1Limit lockout - main limit open over 3 minutesHigh
14Ignition lockoutCritical
14.1Ignition lockout after 4 triesHigh
14.2Lockout - flame lost 3 times after 70 s of heatingHigh
14.3Lockout - 7 flame-loss events in one heat callHigh
15Blower motor lockoutHigh
21Gas heating lockoutCritical
21.124 VAC on gas valve when it should be offCritical
22Abnormal flame-proving signalCritical
22.1False flameCritical
23Pressure switch did not openMedium
23.1Main pressure switch stuck closedMedium
23.2Secondary pressure switch stuck closedMedium
24Secondary (24 V) fuse openMedium
24.1Fuse fault (24 V)High
25Invalid model selection or setup errorMedium
25.1No program in controlHigh
25.2Corrupted program fileHigh
25.3Twinned furnaces not identicalMedium
25.4Main program invalid, running on backupLow
25.5Installer settings corruptedLow
25.6Wrong program for this controlHigh
25.7Non-condensing program in condensing furnaceHigh
27.1Super plug program missing or corruptedMedium
27.2Super plug program missing or corruptedMedium
27.3Super plug program missing or corruptedMedium
31High-heat pressure switch or relay did not close or reopenedHigh
31.2Secondary pressure switch (HPS) openHigh
31.3Secondary pressure switch lockoutHigh
32Low-heat pressure switch did not close or reopenedHigh
32.1Main pressure switch (LPS) openHigh
33Limit circuit faultHigh
33.1Main limit circuit switch openHigh
34Ignition proving failureHigh
34.1Ignition fault during ignition trialsHigh
34.2Flame lost before blower on-delayMedium
34.3Flame lost after blower on-delayHigh
43Low-heat pressure switch open while high-heat switch closedHigh
45Control circuitry lockoutHigh
45.1Control failure - flame circuit / memory / sequenceHigh
45.2Control failure - gas valve relay will not closeHigh
45.3Control failure - EEPROM memoryHigh
46.1Momentary loss of powerLow
LED OFFNo amber LED - no power to controlHigh
Rapid FlashReversed 115-V polarity (or twinning phasing)High

Find codes by Carrier model

58SB0A/58SB1A

58SB0A045E14--1258SB0A045E17--1258SB0A070E14--1258SB0A070E17--1258SB0A070E17--1658SB0A070E21--1658SB0A090E17--1458SB0A090E21--1658SB0A090E21--2058SB0A090E24--2058SB0A110E21--2058SB0A110E24--2058SB0A135E24--2058SB0A155E24--20

59MN7C

59MN7C060C17--1459MN7C060C21--2059MN7C080C17--1459MN7C080C21--2059MN7C100C21--2259MN7C120C24--22

59SC6A

59SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22

59TP6A

59TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22

Payne PG96VTA

PG96VTA30040APG96VTA36040BPG96VTA36060APG96VTA48060BPG96VTA48080BPG96VTA60080CPG96VTA60100CPG96VTA66120D

Furnace troubleshooting guides

Carrier Furnace specs and setup data

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.