Carrier Air Conditioner: Charging a system with flammable refrigerant

Updated · by Aurora Star Tech Inc.

Charging a system with flammable refrigerant on a Carrier air conditioner: Charging and leak-test steps for R454B / flammable refrigerant systems.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Flammable refrigerant systems

How to fix charging a system with flammable refrigerant: step by step

  1. Use only tools approved for flammable refrigerants.
  2. Keep charging hoses as short as possible.
  3. Make sure charging equipment does not contaminate refrigerants.
  4. Keep cylinders upright.
  5. Earth the refrigeration system before charging.
  6. Do not overfill the system.
  7. Pressure test with oxygen-free nitrogen (OFN) before recharging.
  8. Leak test after charging and before commissioning.
  9. Run a follow-up leak test before leaving the site.
  10. Label the system when charging is complete.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Conditioner codes

Source: Carrier D5FUHA installation instructions, p. 8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.