Carrier Air Conditioner: Charging a system with flammable refrigerant
Charging a system with flammable refrigerant on a Carrier air conditioner: Charging and leak-test steps for R454B / flammable refrigerant systems.
Applies to: Flammable refrigerant systems
How to fix charging a system with flammable refrigerant: step by step
- Use only tools approved for flammable refrigerants.
- Keep charging hoses as short as possible.
- Make sure charging equipment does not contaminate refrigerants.
- Keep cylinders upright.
- Earth the refrigeration system before charging.
- Do not overfill the system.
- Pressure test with oxygen-free nitrogen (OFN) before recharging.
- Leak test after charging and before commissioning.
- Run a follow-up leak test before leaving the site.
- Label the system when charging is complete.
If the unit shows an error code, look it up: Carrier Air Conditioner codes
Source: Carrier D5FUHA installation instructions, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.