Carrier 59SC6A080M17--16 error codes list

CodeMeaningSeverity
##.#Active status code shown as major.minor numberLow
10.1L1 polarity faultHigh
12.1W (heat call) on at power upLow
13.1Limit lockout - main limit open over 3 minutesHigh
14.1Ignition lockout after 4 triesHigh
14.2Lockout - flame lost 3 times after 70 s of heatingHigh
14.3Lockout - 7 flame-loss events in one heat callHigh
21.124 VAC on gas valve when it should be offCritical
22.1False flameCritical
23.1Main pressure switch stuck closedMedium
23.2Secondary pressure switch stuck closedMedium
24.1Fuse fault (24 V)High
25.1No program in controlHigh
25.2Corrupted program fileHigh
25.3Twinned furnaces not identicalMedium
25.4Main program invalid, running on backupLow
25.5Installer settings corruptedLow
25.6Wrong program for this controlHigh
25.7Non-condensing program in condensing furnaceHigh
27.1Super plug program missing or corruptedMedium
27.2Super plug program missing or corruptedMedium
27.3Super plug program missing or corruptedMedium
31.2Secondary pressure switch (HPS) openHigh
31.3Secondary pressure switch lockoutHigh
32.1Main pressure switch (LPS) openHigh
33.1Main limit circuit switch openHigh
34.1Ignition fault during ignition trialsHigh
34.2Flame lost before blower on-delayMedium
34.3Flame lost after blower on-delayHigh
45.1Control failure - flame circuit / memory / sequenceHigh
45.2Control failure - gas valve relay will not closeHigh
45.3Control failure - EEPROM memoryHigh
46.1Momentary loss of powerLow
bLrBlower running (secondary furnace / communicating system)Low
CfnContinuous fanLow
CLCooling or heat pump running (59SC6A)Low
ClrClear fault historyLow
CodMenu: cool blower-off delayLow
CtMenu: component testLow
dirMenu: display orientationLow
dnFDisplay set for downflowLow
EndComponent test - endLow
ErrComponent test could not startLow
FLtMenu: last 7 faultsLow
FnComponent test - blowerLow
HoDMenu: heat blower-off delayLow
HpdHeat pump defrost - furnace heatingLow
HSiComponent test - hot surface igniterLow
HtHeating (59SC6A, 59MN7C menu: heating airflow setting)Low
iDlIdle - standby, no demandLow
inFMenu: program number and softwareLow
nonNo faults storedLow
PRGStartup display - model program numberLow
PriTwinning: primary furnaceLow
PUrComponent test - purge (inducer on)Low
rStMenu: reset to factory defaultsLow
SECTwinning: secondary furnaceLow
tnnMenu: twinningLow
tStComponent test startedLow
uErStartup display - software versionLow
UPFDisplay set for upflowLow
YEsReset confirmationLow

Troubleshooting the 59SC6A080M17--16

Carrier 59SC6A080M17--16 specs and setup data

All Carrier Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977