Carrier Error Code 25.6: Wrong program for this control (Furnace)

Updated · by Aurora Star Tech Inc.

Carrier error code 25.6 on a furnace means: Wrong program for this control. It is also called Carrier diagnostic code 25.6.

High severityFurnace59SC6A

Homeowner? What Carrier code 25.6 means for you

Call a technician Your furnace is reporting: Wrong program for this control. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code 25.6 mean?

The program loaded doesn't match this control hardware; gas heat will not run.

Applies to: Carrier 59SC6A

Common causes of Carrier code 25.6

  • Wrong program loaded during board replacement
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code 25.6

59SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22

Other Carrier Furnace codes

CodeMeaning
25Invalid model selection or setup error
25.1No program in control
25.2Corrupted program file
25.3Twinned furnaces not identical
25.4Main program invalid, running on backup
25.5Installer settings corrupted
25.7Non-condensing program in condensing furnace
27.1Super plug program missing or corrupted
27.2Super plug program missing or corrupted
27.3Super plug program missing or corrupted
31High-heat pressure switch or relay did not close or reopened
31.2Secondary pressure switch (HPS) open

All Carrier Furnace error codes →

Carrier code 25.6: homeowner questions

What does Carrier code 25.6 mean?

Wrong program for this control. The program loaded doesn't match this control hardware; gas heat will not run.

Is it safe to keep using my furnace with code 25.6?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code 25.6 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code 25.6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code 25.6 near me?

Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Carrier 59SC6A Installation, Start-up, Operating and Service Instructions, Fig. 60 Service Label Information, p.54; Control Board Replacement p.53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.