Carrier Error Code Pri: Twinning: primary furnace (Furnace)
Carrier error code Pri on a furnace means: Twinning: primary furnace. It is also called Carrier diagnostic code Pri.
Homeowner? What Carrier code Pri means for you
Usually minor Your furnace is reporting: Twinning: primary furnace. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Carrier error code Pri mean?
Choice inside the tnn menu: this furnace is the primary of a twinned pair.
Applies to: 59SC6A and Payne PG96VTA furnaces
Carrier models that use code Pri
59SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22PG96VTA30040APG96VTA36040BPG96VTA36060APG96VTA48060BPG96VTA48080BPG96VTA60080CPG96VTA60100CPG96VTA66120D
Other Carrier Furnace codes
All Carrier Furnace error codes →
Carrier code Pri: homeowner questions
What does Carrier code Pri mean?
Twinning: primary furnace. Choice inside the tnn menu: this furnace is the primary of a twinned pair.
Is it safe to keep using my furnace with code Pri?
Usually yes. Code Pri is normally minor, but if it keeps coming back have it checked.
Can I reset Carrier code Pri myself?
You can try one reset (power off for 30 seconds, then on). If Carrier code Pri comes back, the cause is still there and a licensed technician should check it.
Who can fix Carrier code Pri near me?
Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Carrier 59SC6A installation instructions, Table 21, p.53; Payne PG96VTAB installation instructions, Main Menu Options, p.53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.