Carrier Error Code EH C1: Refrigerant sensor detects leakage (Mini-Split)

Updated · by Aurora Star Tech Inc.

Carrier error code EH C1 on a mini-split means: Refrigerant sensor detects leakage. It is also called Carrier diagnostic code EH C1.

Critical severityMini-SplitD5FSFA

Homeowner? What Carrier code EH C1 means for you

Stop and call Your ductless mini-split is reporting: Refrigerant sensor detects leakage. This code is a safety shutdown. Turn the ductless mini-split off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code EH C1 mean?

The sensor reads at least 10% of LFL for 10 s, or the multi-zone system receives a leakage protection fault from the outdoor unit. In multi-zone systems only the leaking indoor unit's buzzer sounds (10 s to 5 min). Other indoor units show the code without sounding. Any key on the remote, wired controller or app silences the alarm.

Applies to: D5FSFAH

Common causes of Carrier code EH C1

  • Refrigerant leak
  • Refrigerant sensor reading high concentration
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code EH C1

D5FSFAH09XAKD5FSFAH12XAKD5FSFAH16XAK

Other Carrier Mini-Split codes

CodeMeaning
EH 66Indoor temperature sensor open or shorted
EHb3Communication error between wire and master control
EH b3Communication fault between wired controller and indoor master control
EHbACommunication error between indoor unit and external fan module
EH bACommunication error between indoor unit and external fan module
EHC1Refrigerant sensor detects leakage
EHC2Refrigerant sensor out of range with leakage detected
EH C2Refrigerant sensor out of range and leakage detected
EHC3Refrigerant sensor out of range
EH C3Refrigerant sensor out of range
EL0CRefrigerant leak detected
EL 0CSystem lacks refrigerant

All Carrier Mini-Split error codes →

Carrier code EH C1: homeowner questions

What does Carrier code EH C1 mean?

Refrigerant sensor detects leakage. The sensor reads at least 10% of LFL for 10 s, or the multi-zone system receives a leakage protection fault from the outdoor unit. In multi-zone systems only the leaking indoor unit's buzzer sounds (10 s to 5 min). Other indoor units show…

Is it safe to keep using my ductless mini-split with code EH C1?

No. Code EH C1 is a safety shutdown, so keep the ductless mini-split off until a licensed technician has checked it.

Can I reset Carrier code EH C1 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Carrier code EH C1 near me?

Aurora Star Tech Inc. repairs Carrier ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FSFAH service manual, p. 45. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.