Carrier Error Code Rapid Flash: Reversed 115-V polarity (or twinning phasing) (Furnace)
Carrier error code Rapid Flash on a furnace means: Reversed 115-V polarity (or twinning phasing). It is also called Carrier diagnostic code Rapid Flash.
Homeowner? What Carrier code Rapid Flash means for you
Call a technician Your furnace is reporting: Reversed 115-V polarity (or twinning phasing). The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Carrier error code Rapid Flash mean?
LED blinks rapidly with no pause and the furnace will not heat; line-voltage polarity is reversed, or on twinned units the 24-V transformers are out of phase.
Applies to: 59TP6A two-stage variable-speed ECM multipoise condensing gas furnace, all sizes (040-10 to 120-22)
Common causes of Carrier code Rapid Flash
- 115-V line and neutral reversed
- Twinned furnaces with incorrect 24-V transformer phasing
- Missing earth ground (control needs it)
Carrier models that use code Rapid Flash
Show all 22 models
58SB0A045E14--1258SB0A045E17--1258SB0A070E14--1258SB0A070E17--1258SB0A070E17--1658SB0A070E21--1658SB0A090E17--1458SB0A090E21--1658SB0A090E21--2058SB0A090E24--2058SB0A110E21--2058SB0A110E24--2058SB0A135E24--2058SB0A155E24--2059TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22
Other Carrier Furnace codes
All Carrier Furnace error codes →
Carrier code Rapid Flash: homeowner questions
What does Carrier code Rapid Flash mean?
Reversed 115-V polarity (or twinning phasing). LED blinks rapidly with no pause and the furnace will not heat; line-voltage polarity is reversed, or on twinned units the 24-V transformers are out of phase.
Is it safe to keep using my furnace with code Rapid Flash?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Carrier code Rapid Flash myself?
You can try one reset (power off for 30 seconds, then on). If Carrier code Rapid Flash comes back, the cause is still there and a licensed technician should check it.
Who can fix Carrier code Rapid Flash near me?
Aurora Star Tech Inc. repairs Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Carrier 59TP6A Installation, Start-up, Operating and Service Instructions, Fig. 66 Troubleshooting Guide, p.88; Electrical Controls and Wiring, p.76. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.