Rheem Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Rheem error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Rheem error codes by equipment type

Rheem Furnace error codes

CodeMeaning
1 blinkSoft lockout (failed ignition)
2 blinksPressure switch circuit open
3 blinksLimit circuit open
4 blinksPressure switch circuit closed (stuck closed)
5 blinksTwinning fault (optional)
6 blinksLine and neutral reversed
10One-hour lockout
11Failed ignition
12Low flame sense
13Flame lost
14Unexpected flame
20Twinning fault
22Main limit open
23HALC limit open (HALC LIMIT OPEN)
26Line and neutral reversed
33Rollout switch (MRLC) open
44Low pressure switch closed (stuck)
45Low pressure switch open - inducer high speed
46Low pressure switch open - inducer low speed
55Pressure switch stuck closed
57Pressure switch stuck open
58Water sense circuit open
59Water sensed / blocked drain
60Blower fault - running (BLWR FLT-RUN)
61Blower fault - blower not running
66Blower overspeed (BLOWER OVRSPEED)
68No blower communication (NO BLWR COMM)
82Supply air sensor fault (SA SENSOR FLT)
93Internal control fault
d1No shared data (NO SHARED DATA)
d4Memory card invalid (MEM CARD INVALD)
d5Card/hardware conflict (CARD-HRD CNFLCT)
d6Blower HP conflict (BLWR HP CNFLCT)
d7Blower manufacturer conflict (BLWR MFG CNFLCT)
d8Old shared data (OLD SHARED DATA)
Flame LED offNo flame sensed (troubleshooting aid)
Flame LED rapid blinkAmber flame LED - unexpected flame
Flame LED slow blinkAmber flame LED - marginal flame sense
h flashingCalibrating (CALIBRATE-NO V)
rLockout indicator

Rheem Heat Pump error codes

CodeMeaning
01Long run time (compressor)
1 flash (L terminal)L-terminal fault output: Long run cycle or low pressure
02High side fault (compressor limit opened 4 times)
2 flashes (L terminal)L-terminal fault output: High pressure control trip
03Short cycling
3 flashes (L terminal)L-terminal fault output: Unit short cycling
4 flashes (L terminal)L-terminal fault output: Locked rotor
05Open circuit - compressor will not run
5 flashes (L terminal)L-terminal fault output: Compressor will not run, open circuit
06Compressor open start circuit
6 flashes (L terminal)L-terminal fault output: Open start circuit
07Compressor open run circuit
7 flashes (L terminal)L-terminal fault output: Open run circuit
8 flashes (L terminal)L-terminal fault output: Control mis-operation
09Low secondary (control) voltage
9 flashes (L terminal)L-terminal fault output: Low control voltage
21Low pressure control (LPC) open
27Low line voltage or no line voltage
28High line voltage
29High pressure control (HPC) open
30ICC fuse open
80Low airflow
83Condenser coil temperature sensor fault
84Outdoor ambient temperature sensor fault
90Communication fault
93Internal control fault
d1No shared data
d3Airflow CFM mismatch
d4Memory card invalid for device
d8Old shared data
Flashing c / C / h / HAnti-short-cycle (3 min) or minimum-run (30 s) timer active
L4Locked rotor lockout
L6Open start circuit lockout
L7Open run circuit lockout
L21Low pressure control lockout
L29High pressure control lockout
PCompressor protector trip

Find codes by Rheem model

Rheem 90RJ/90TJ 90 Plus

90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12

R95P

R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA

Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)

R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA

RGPE/RGLE

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Rheem (-)GRC/(-)GTC 90 Plus

RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS

Rheem RGRM/RGTM 90 Plus

RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10

Rheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.