Rheem Error Code 07: Compressor open run circuit (Heat Pump)

Updated · by Aurora Star Tech Inc.

Rheem error code 07 on a heat pump means: Compressor open run circuit. It is also called Rheem diagnostic code 07.

High severityHeat PumpRheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

Homeowner? What Rheem code 07 means for you

Call a technician Your heat pump is reporting: Compressor open run circuit. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code 07 mean?

The ICC sees current in the start circuit but none in the run circuit. Repeated four (4) times in one call gives lockout L7. Reported as 7 flashes on the L terminal.

Applies to: (-)PRL-JEC 2-stage 16 SEER heat pumps: RPRL/UPRL-024JEC, -036JEC, -048JEC, -060JEC

Common causes of Rheem code 07

  • Damaged, wrong or miswired run capacitor
  • Broken wire or loose connector in the run circuit
  • Open run winding
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code 07

RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC

Other Rheem Heat Pump codes

CodeMeaning
3 flashes (L terminal)L-terminal fault output: Unit short cycling
4 flashes (L terminal)L-terminal fault output: Locked rotor
05Open circuit - compressor will not run
5 flashes (L terminal)L-terminal fault output: Compressor will not run, open circuit
06Compressor open start circuit
6 flashes (L terminal)L-terminal fault output: Open start circuit
7 flashes (L terminal)L-terminal fault output: Open run circuit
8 flashes (L terminal)L-terminal fault output: Control mis-operation
09Low secondary (control) voltage
9 flashes (L terminal)L-terminal fault output: Low control voltage
21Low pressure control (LPC) open
27Low line voltage or no line voltage

All Rheem Heat Pump error codes →

Rheem code 07: homeowner questions

What does Rheem code 07 mean?

Compressor open run circuit. The ICC sees current in the start circuit but none in the run circuit. Repeated four (4) times in one call gives lockout L7. Reported as 7 flashes on the L terminal.

Is it safe to keep using my heat pump with code 07?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Rheem code 07 myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code 07 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code 07 near me?

Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Rheem (-)PRL-JEC Heat Pump Installation Instructions, 12.6 ICC Diagnostic Codes, p.29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.