Rheem Error Code 02: High side fault (compressor limit opened 4 times) (Heat Pump)
Rheem error code 02 on a heat pump means: High side fault (compressor limit opened 4 times). It is also called Rheem diagnostic code 02.
Homeowner? What Rheem code 02 means for you
Call a technician Your heat pump is reporting: High side fault (compressor limit opened 4 times). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code 02 mean?
Compressor limit has opened four (4) times within one call for operation. The manual's code table is layered with an older draft that calls 02 'High Pressure Control Open' and points to codes 21/L21/29/L29; treat 02 as a high-side (high head) problem either way.
Applies to: (-)PRL-JEC 2-stage 16 SEER heat pumps: RPRL/UPRL-024JEC, -036JEC, -048JEC, -060JEC
Common causes of Rheem code 02
- Dirty outdoor coil (cooling)
- Outdoor fan not running (cooling)
- Dirty indoor coil or filter (heating)
A technician checks these and 3 other possible causes on site before replacing any part.
Rheem models that use code 02
RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC
Other Rheem Heat Pump codes
All Rheem Heat Pump error codes →
Rheem code 02: homeowner questions
What does Rheem code 02 mean?
High side fault (compressor limit opened 4 times). Compressor limit has opened four (4) times within one call for operation. The manual's code table is layered with an older draft that calls 02 'High Pressure Control Open' and points to codes 21/L21/29/L29; treat 02 as a high-side (high…
Is it safe to keep using my heat pump with code 02?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Rheem code 02 myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code 02 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code 02 near me?
Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Rheem (-)PRL-JEC Heat Pump Installation Instructions, 12.6 ICC Diagnostic Codes, p.29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.