Rheem Furnace: Burners go out before the heat call ends / short cycling

Updated · by Aurora Star Tech Inc.

Burners go out before the heat call ends / short cycling on a Rheem furnace: Main burners do not stay lit until the thermostat is satisfied, or the room temperature is not held near setpoint.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Rheem (-)GRC/(-)GTC and 90RJ/90TJ 90 Plus condensing gas furnaces

Common causes of burners go out before the heat call ends / short cycling

  • Pressure switch dropping out
  • Limit opening (airflow, over-firing, rollout)
  • Weak flame sense
  • Thermostat location, anticipator setting, compatibility
  • Oversized furnace

How to fix burners go out before the heat call ends / short cycling: step by step

  1. Check whether the pressure switch drops out during the run (see 2 blinks).
  2. Check whether the limit circuit or the IDM wire through the aux. limit opens and closes - STATUS should show 3 blinks; check airflow, limits, rollouts and over-firing.
  3. Confirm the FLAME LED is steady on with burners lit; if blinking or off, clean the flame sensor and check ground/polarity.
  4. Make sure the thermostat is not affected by registers, fans, sunlight, heat through walls, pipes or wires in walls.
  5. Check the heat anticipator setting; the furnace may need an isolation relay (SPST, 24 VAC coil, contacts rated 0.5 A min at 24 V).
  6. Verify the furnace is correctly sized.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

Rheem 90RJ/90TJ 90 Plus

90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12

R95P

R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA

Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)

R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA

RGPE/RGLE

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Rheem (-)GRC/(-)GTC 90 Plus

RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS

Rheem RGRM/RGTM 90 Plus

RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10

Source: Rheem (-)GRC/(-)GTC Installation Instructions 92-24161-88-00, Figure 56 IFC Troubleshooting Guide, p.54 (printed); Rheem 90RJ/90TJ Installation Instructions 92-24161-32-08, Figure 53, p.54. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.