Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rheem Error Code d1: No shared data (NO SHARED DATA) (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code d1 on a furnace means: No shared data (NO SHARED DATA). It is also called Rheem diagnostic code d1.

Critical severityFurnaceRGPE/RGLE · R96V/96MDV

Homeowner? What Rheem code d1 means for you

Stop and call Your furnace is reporting: No shared data (NO SHARED DATA). This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code d1 mean?

No valid furnace shared data on the memory card or network; furnace will not run in any mode. Level 2 fault. Thermostat also shows Call For Service / CHECK FURNACE to the homeowner.

Applies to: RGPE/RGLE 2-stage 80+

Common causes of Rheem code d1

  • Replacement IFC installed without the original memory card
  • Card missing/invalid and no copy on the communicating network
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code d1

96MDV115D50ARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
AFAirflow readout (pushbutton status menu)
Blank thermostat text areaThermostat text area blank - system found OK
Blinking decimal pointAirflow readout - blinks of right decimal point
CCooling or heat-pump heat (compressor call)
cd / CdDehumidification cooling
CFM LED blinksCFM LED blink count = target airflow
d4No valid model data on memory card
d5Card/hardware conflict (CARD-HRD CNFLCT)
d6Blower HP conflict (BLWR HP CNFLCT)
d7Blower manufacturer conflict (BLWR MFG CNFLCT)
d8Old shared data (OLD SHARED DATA)
dFDefrost in progress (dual fuel)

All Rheem Furnace error codes →

Rheem code d1: homeowner questions

What does Rheem code d1 mean?

No shared data (NO SHARED DATA). No valid furnace shared data on the memory card or network; furnace will not run in any mode. Level 2 fault. Thermostat also shows Call For Service / CHECK FURNACE to the homeowner.

Is it safe to keep using my furnace with code d1?

No. Code d1 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Rheem code d1 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Rheem code d1 near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: RGPE/RGLE: Table 16 p.49 / Table 20; memory card rules p.38-39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair