Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rheem Error Code CFM LED blinks: CFM LED blink count = target airflow (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code CFM LED blinks on a furnace means: CFM LED blink count = target airflow. It is also called Rheem diagnostic code CFM LED blinks.

Low severityFurnaceRheem RGRM/RGTM 90 Plus

Homeowner? What Rheem code CFM LED blinks means for you

Usually minor Your furnace is reporting: CFM LED blink count = target airflow. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code CFM LED blinks mean?

The CFM LED on the RGRM/RGTM control reports the blower's target airflow by blinking. One full blink is 100 CFM and a half blink is about 50 CFM, followed by a pause of about one second before the count repeats. Example: eleven and a half blinks means roughly 1150 CFM. It is a target value and only a rough guide, not a measurement.

Applies to: Rheem RGRM/RGTM 90 Plus furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code CFM LED blinks

RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10

Other Rheem Furnace codes

CodeMeaning
93Internal control fault
AFAirflow readout (pushbutton status menu)
Blank thermostat text areaThermostat text area blank - system found OK
Blinking decimal pointAirflow readout - blinks of right decimal point
CCooling or heat-pump heat (compressor call)
cd / CdDehumidification cooling
d1No shared data (NO SHARED DATA)
d4Memory card invalid (MEM CARD INVALD)
d5Card/hardware conflict (CARD-HRD CNFLCT)
d6Blower HP conflict (BLWR HP CNFLCT)
d7Blower manufacturer conflict (BLWR MFG CNFLCT)
d8Old shared data (OLD SHARED DATA)

All Rheem Furnace error codes →

Rheem code CFM LED blinks: homeowner questions

What does Rheem code CFM LED blinks mean?

CFM LED blink count = target airflow. The CFM LED on the RGRM/RGTM control reports the blower's target airflow by blinking. One full blink is 100 CFM and a half blink is about 50 CFM, followed by a pause of about one second before the count repeats. Example: eleven and a half…

Is it safe to keep using my furnace with code CFM LED blinks?

Usually yes. Code CFM LED blinks is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code CFM LED blinks myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code CFM LED blinks comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code CFM LED blinks near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Rheem RGRM Installation Instructions (Nature Air), Flame, Status, Power and CFM LED descriptions, p.53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977