Rheem Error Code d: Defrost active (Heat Pump)
Rheem error code d on a heat pump means: Defrost active. It is also called Rheem diagnostic code d.
Homeowner? What Rheem code d means for you
Usually minor Your heat pump is reporting: Defrost active. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code d mean?
Lowercase d on the display while the unit is in a defrost cycle in heating mode. Normal. A demand defrost ends after 14 minutes or when the coil reaches the termination temperature (70 F as shipped).
Applies to: Rheem/Ruud PRL-JEC heat pumps with Comfort Control2 ICC
Rheem models that use code d
RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC
Other Rheem Heat Pump codes
All Rheem Heat Pump error codes →
Rheem code d: homeowner questions
What does Rheem code d mean?
Defrost active. Lowercase d on the display while the unit is in a defrost cycle in heating mode. Normal. A demand defrost ends after 14 minutes or when the coil reaches the termination temperature (70 F as shipped).
Is it safe to keep using my heat pump with code d?
Usually yes. Code d is normally minor, but if it keeps coming back have it checked.
Can I reset Rheem code d myself?
You can try one reset (power off for 30 seconds, then on). If Rheem code d comes back, the cause is still there and a licensed technician should check it.
Who can fix Rheem code d near me?
Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Rheem PRL-JEC Installation Instructions, Comfort Control2 section 12.3 and 12.6, pp.19-25; sections 8.1-8.2 Defrost. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.