Rheem Error Code Power LED on: Power LED on – control has 24 VAC (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code Power LED on on a furnace means: Power LED on - control has 24 VAC. It is also called Rheem diagnostic code Power LED on.

Low severityFurnaceRheem RGRM/RGTM 90 Plus

Homeowner? What Rheem code Power LED on means for you

Usually minor Your furnace is reporting: Power LED on - control has 24 VAC. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code Power LED on mean?

The POWER LED on the RGRM/RGTM control is lit whenever the board is receiving 24 VAC, so the control is powered. If it is dark there is no 24 V at the board (check transformer, fuse, door switch).

Applies to: Rheem RGRM/RGTM 90 Plus furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code Power LED on

RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10

Other Rheem Furnace codes

CodeMeaning
FURNACE FOUNDThermostat start-up message - equipment found
HGas heat on
h (lowercase)Low-fire gas heat on
h flashingCalibrating (CALIBRATE-NO V)
HPHeat-pump heat running (dual fuel)
Learn buttonLearn button - RX LED rapid blink test
rLockout indicator
RX LED blinkingGreen RX LED - network traffic present
SEARCHINGThermostat start-up message - searching
SETUP menuFurnace user menu - SETUP
STAT LED double blinkRed STAT LED - two slow blinks at power-up
STATUS 1 menuFurnace user menu - STATUS 1

All Rheem Furnace error codes →

Rheem code Power LED on: homeowner questions

What does Rheem code Power LED on mean?

Power LED on - control has 24 VAC. The POWER LED on the RGRM/RGTM control is lit whenever the board is receiving 24 VAC, so the control is powered. If it is dark there is no 24 V at the board (check transformer, fuse, door switch).

Is it safe to keep using my furnace with code Power LED on?

Usually yes. Code Power LED on is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code Power LED on myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code Power LED on comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code Power LED on near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Rheem RGRM Installation Instructions (Nature Air), Flame, Status, Power and CFM LED descriptions, p.53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977