Updated · by Aurora Star Tech Inc.

Rheem error code Flame LED steady on on a furnace means: Amber flame LED steady - normal flame sensed. It is also called Rheem diagnostic code Flame LED steady on.

Low severityFurnaceRheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC) · R95P · Rheem (-)GRC/(-)GTC 90 Plus · Rheem 90RJ/90TJ 90 Plus · Rheem RGRM/RGTM 90 Plus

Homeowner? What Rheem code Flame LED steady on means for you

Usually minor Your furnace is reporting: Amber flame LED steady - normal flame sensed. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code Flame LED steady on mean?

The amber FLAME LED on the integrated furnace control stays continuously lit when the burners are lit and the flame sensor sees a good flame. Off = no flame, slow blink = weak/marginal flame, rapid blink = flame sensed when none should be there. Steady on during the burn is the normal state.

Applies to: Rheem/Ruud (-)802P / 80MDP 80% two-stage furnaces; R95P; Rheem (-)GRC/(-)GTC and 90RJ/90TJ 90 Plus; RGRM/RGTM 90 Plus

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code Flame LED steady on

Show all 44 models

90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSAR802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSARGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJSRGTM-06RGTM-07RGTM-09RGTM-10

Other Rheem Furnace codes

CodeMeaning
Fault recall - last 5Power-up replay of the last five faults
FIXED FIRE RATEForced low or high fire test (SETUP menu)
FLFault history (pushbutton status menu)
Flame LED offNo flame sensed (troubleshooting aid)
Flame LED rapid blinkAmber flame LED - unexpected flame
Flame LED slow blinkAmber flame LED - marginal flame sense
FrFire rate readout (pushbutton status menu)
FURNACE FOUNDThermostat start-up message - equipment found
HGas heat on
h (lowercase)Low-fire gas heat on
h flashingCalibrating (CALIBRATE-NO V)
HPHeat-pump heat running (dual fuel)

All Rheem Furnace error codes →

Rheem code Flame LED steady on: homeowner questions

What does Rheem code Flame LED steady on mean?

Amber flame LED steady - normal flame sensed. The amber FLAME LED on the integrated furnace control stays continuously lit when the burners are lit and the flame sensor sees a good flame. Off = no flame, slow blink = weak/marginal flame, rapid blink = flame sensed when none should be…

Is it safe to keep using my furnace with code Flame LED steady on?

Usually yes. Code Flame LED steady on is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code Flame LED steady on myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code Flame LED steady on comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code Flame LED steady on near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: 802PA Flame Status LED (pp.43-44) and Diagnostics flowchart; R95P Flame Status LED (printed p.90); 90RJ and GRC troubleshooting chart (Flame (Amber) LED codes); RGRM Flame LED description p.53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.