Rheem Error Code 84: Outdoor ambient temperature sensor fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Rheem error code 84 on a heat pump means: Outdoor ambient temperature sensor fault. It is also called Rheem diagnostic code 84.

Low severityHeat PumpRheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

Homeowner? What Rheem code 84 means for you

Usually minor Your heat pump is reporting: Outdoor ambient temperature sensor fault. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code 84 mean?

The ambient sensor reads an abnormally low or high outdoor temperature. With a failed ambient sensor, the control defrosts every 34 minutes in heat mode with coil below 35°F.

Applies to: (-)PRL-JEC 2-stage 16 SEER heat pumps: RPRL/UPRL-024JEC, -036JEC, -048JEC, -060JEC

Common causes of Rheem code 84

  • Failed ambient sensor
  • Unit in an unusually hot location
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code 84

RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC

Other Rheem Heat Pump codes

CodeMeaning
27Low line voltage or no line voltage
28High line voltage
29High pressure control (HPC) open
30ICC fuse open
80Low airflow
83Condenser coil temperature sensor fault
90Communication fault
93Internal control fault
cFirst-stage cooling
C (upper case)Second-stage cooling
dDefrost active
d1No shared data

All Rheem Heat Pump error codes →

Rheem code 84: homeowner questions

What does Rheem code 84 mean?

Outdoor ambient temperature sensor fault. The ambient sensor reads an abnormally low or high outdoor temperature. With a failed ambient sensor, the control defrosts every 34 minutes in heat mode with coil below 35°F.

Is it safe to keep using my heat pump with code 84?

Usually yes. Code 84 is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code 84 myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code 84 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code 84 near me?

Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Rheem (-)PRL-JEC Heat Pump Installation Instructions, 12.6 ICC Diagnostic Codes, p.30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.