Rheem Error Code Fault recall: Power-up replay of the last three faults (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code Fault recall on a furnace means: Power-up replay of the last three faults. It is also called Rheem diagnostic code Fault recall.

Low severityFurnaceRheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC) · R95P

Homeowner? What Rheem code Fault recall means for you

Usually minor Your furnace is reporting: Power-up replay of the last three faults. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code Fault recall mean?

After the furnace control is power-cycled, the seven-segment display replays the three most recent faults younger than one week, newest first, as a diagnostic aid. Faults older than a week drop out of the memory by themselves. Seeing an old code here does not mean the fault is active now.

Applies to: Rheem/Ruud (-)802P / 80MDP 80% two-stage furnaces; R95P furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code Fault recall

R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSAR802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA

Other Rheem Furnace codes

CodeMeaning
d6Blower HP conflict (BLWR HP CNFLCT)
d7Blower manufacturer conflict (BLWR MFG CNFLCT)
d8Old shared data (OLD SHARED DATA)
dFDefrost in progress (dual fuel)
FContinuous fan on
FAULT HISTORY menuFurnace user menu - FAULT HISTORY
Fault recall - last 5Power-up replay of the last five faults
FIXED FIRE RATEForced low or high fire test (SETUP menu)
FLFault history (pushbutton status menu)
Flame LED offNo flame sensed (troubleshooting aid)
Flame LED rapid blinkAmber flame LED - unexpected flame
Flame LED slow blinkAmber flame LED - marginal flame sense

All Rheem Furnace error codes →

Rheem code Fault recall: homeowner questions

What does Rheem code Fault recall mean?

Power-up replay of the last three faults. After the furnace control is power-cycled, the seven-segment display replays the three most recent faults younger than one week, newest first, as a diagnostic aid. Faults older than a week drop out of the memory by themselves. Seeing an…

Is it safe to keep using my furnace with code Fault recall?

Usually yes. Code Fault recall is normally minor, but if it keeps coming back have it checked.

Can I reset Rheem code Fault recall myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code Fault recall comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code Fault recall near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Rheem (-)802PA Installation Instructions, Diagnostics and Fault Codes (UT 1028-928 control), pp.40-41; Flame Status LED and Fault Recall (pp.43-44); R95P Fault Recall (printed p.90). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977