Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rheem Error Code 03: Short cycling (Heat Pump)

Updated · by Aurora Star Tech Inc.

Rheem error code 03 on a heat pump means: Short cycling. It is also called Rheem diagnostic code 03.

Medium severityHeat PumpRheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC)

Homeowner? What Rheem code 03 means for you

Check, then call Your heat pump is reporting: Short cycling. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code 03 mean?

The last four (4) compressor cycles each ran less than three (3) minutes. Reported as 3 flashes on the L terminal.

Applies to: (-)PRL-JEC 2-stage 16 SEER heat pumps: RPRL/UPRL-024JEC, -036JEC, -048JEC, -060JEC

Common causes of Rheem code 03

  • Loose or bad thermostat wiring (R, C, 1, 2)
  • Thermostat located too close to a supply register
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code 03

RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC

Other Rheem Heat Pump codes

CodeMeaning
0Standby - no call for operation
01Long run time (compressor)
1 flash (L terminal)L-terminal fault output: Long run cycle or low pressure
02High side fault (compressor limit opened 4 times)
2 flashes (L terminal)L-terminal fault output: High pressure control trip
3 flashes (L terminal)L-terminal fault output: Unit short cycling
4 flashes (L terminal)L-terminal fault output: Locked rotor
05Open circuit - compressor will not run
5 flashes (L terminal)L-terminal fault output: Compressor will not run, open circuit
06Compressor open start circuit
6 flashes (L terminal)L-terminal fault output: Open start circuit
07Compressor open run circuit

All Rheem Heat Pump error codes →

Rheem code 03: homeowner questions

What does Rheem code 03 mean?

Short cycling. The last four (4) compressor cycles each ran less than three (3) minutes. Reported as 3 flashes on the L terminal.

Is it safe to keep using my heat pump with code 03?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Rheem code 03 myself?

You can try one reset (power off for 30 seconds, then on). If Rheem code 03 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rheem code 03 near me?

Aurora Star Tech Inc. repairs Rheem heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Rheem (-)PRL-JEC Heat Pump Installation Instructions, 12.6 ICC Diagnostic Codes, p.29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977