Rheem Furnace: Cement PVC vent joints
Cement PVC vent joints on a Rheem furnace: Method for joining PVC vent pipe and fittings with cleaner-primer and medium-body solvent cement.
Applies to: PVC vent joints
How to fix cement pvc vent joints: step by step
- Cut the pipe end square, chamfer the edge, and remove all burrs and ragged edges.
- Clean the fitting socket and pipe joint of dirt, grease and moisture.
- Check the pipe fit in the socket.
- Wipe socket and pipe with cleaner-primer and apply a liberal coat inside the socket and outside the pipe.
- Apply a thin coat of cement inside the socket.
- Quickly apply a heavy coat of cement to the pipe end.
- Insert the pipe with a slight twist until it bottoms out.
- Hold the pipe in place for 30 seconds.
- Wipe away excess cement and allow 15 minutes before handling. Cure time varies with fit, temperature and humidity.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.